Is this MODULE for you?
If you answered 'yes' to any of the above, the 'AirFlow' Module is your solution! Brief'Air Flow' MS Excel Spreadsheet Module will assist you in the design of air distribution system. The Module determines the size and number of room air diffusion outlets and the size of the ductwork delivering the conditioned air from air-handling unit to the air diffusers. Sizing Air DiffusersIn everyday design of the air diffuser layout, the engineer faces a dilemma: to accomplish proper time-consuming selection based on the air jet trajectory (throw, horizontal projection) calculated using special air dynamic equations and the noise criterion as recommended by ASHRAE handbooks or to do a quick selection based on the noise criterion only. If he or she follows the first path, the project development cost will overspill the budget. If the second path is followed, the occupants in the spaces may feel cold air draft or stale zones because of improper design. The module solves the dilemma- it will assist you to follow the first path without excessive time waste. Usage
Traditional Ductwork CalculationsUnfortunately, the engineer often simplifies the ductwork design to minimize the design effort and thus compromising the design quality. She uses a standard duct sizing chart to select the duct sizes based on recommended air velocity or and friction loss range and the required airflow rates simulated by a software tool, for example, the Module 'DESIGN LOADS'. She manually enters the sizes into an Excel spreadsheet or drawing and calculates the pressure loss through the sized ductwork using the average friction loss rate and a severe factor accounting for the dampers, transitions and other fitting impact. In the course of the design, the airflow rate is often repeatedly changed, so she needs to repeat the above procedure again. What a time wasting and error prone process! A different issue arises from the manual primitive approach. If the ductwork consists of multiple branch, after the ductwork is constructed, the summarized airflow rates will deviate significantly from the expected values. The use of the balancing dampers to adjust the air flows in many cases causes prohibitive noise created by the air hissing through an almost closed damper. 'Air Flow' Automated Ductwork CalculationsThe 'Air Flow' Module automates and streamlines the process of sizing duct systems for you. It offers tremendous time savings and dramatically improves the accuracy of the results. The Module is coded based on the standard Bernoulli equation and the empirical duct material datasets provided by the ASHRAE Handbook 'Fundamentals', 2005. Usage
Engineers may be interested to follow air pressure balancing procedures as outlined in the guide 'A to Z HVAC Design for Engineers'. The module accuracy has been validated by comparison with the duct sizing chart in the ASHRAE Handbook “Fundementals”, 2005. The module is available in both Inch-Pound and Metric (SI) units.
|
|